Gracey Curette - M5 Deep Scaling (GRA 7/8) for Premolars / Molars, More Sharply Angled - ZEPF-bIONIK QuickFix Handle in Lightred-Magenta, Titanium Inserts | Helmut Zepf No. 24.205.07GM5-TI
The Gracey Curette M5 Deep Scaling (GRA 7/8) is a precision periodontal instrument engineered for effective subgingival scaling and root planing on premolars and molars. Featuring a more sharply angled blade design, this Gracey Curette variant reaches deeper into periodontal pockets and navigates complex root morphologies with exceptional accuracy and control.
bIONIK handle color code
The handle color identifies which instrument you are using. Each bIONIK color stands for a working-end pattern, so you can pick the right curette or scaler from the tray at a glance.
| Handle color | Instrument |
|---|---|
| Front teeth | |
| Yellow | Gracey 1/2 Ā· Langer 5/6 |
| Signal orange | Gracey 3/4 |
| Red-purple | Gracey 5/6 |
| Back teeth | |
| Lightred-magentaThis instrument | Gracey 7/8 Ā· M 23 Ā· sickle 6/7 delicate |
| Turquoise-brightblue | Gracey 9/10 |
| Signal purple | Gracey 11/12, 15/16 |
| Cobalt blue | Gracey 13/14, 17/18 Ā· Columbia Ā· McCall Ā· Langer 17/18 Ā· M 23 slim Ā· sickle 6/7 delicate |
| Universals and sickles | |
| Yellow-green | Langer 3/4 Ā· sickle scalers |
| Black | Langer 1/2 |
| Grey | GXC 4 blunt sickle |
This is a Gracey 7/8 Curette. See all 16 Zepf versions — handles, coatings and replaceable tips — on our Gracey 7/8 Curette page.
Part of the Helmut Zepf QuickFix replaceable-tip system — screw-in tips for bIONIK, Z-SHAPE and Lotus handles. Swap a worn tip in seconds and keep the handle.
Backed by our Helmut Zepf Warranty — this instrument is warranted against defects in materials and workmanship for 6 months. Full terms and how to make a claim are on the Warranty page.
Instrument Design & Features
- Pattern: Gracey 7/8 ā optimized for premolars and molars
- Design: M5 Deep Scaling with a more sharply angled working end for enhanced subgingival access
- Handle: ZEPF-bIONIK in Lightred-Magenta ā ergonomically shaped for reduced hand fatigue during extended clinical procedures
- Inserts: Titanium ā lightweight, corrosion-resistant, and highly durable
- Manufacturer: Helmut Zepf, Germany
Clinical Application
This Gracey Curette is specifically designed for professional periodontal therapy. The GRA 7/8 pattern addresses the buccal and lingual surfaces of posterior teeth, while the M5 deep-scaling geometry enables precise instrumentation in deeper pocket depths. The titanium inserts contribute to a reduced overall instrument weight, supporting tactile sensitivity and minimizing operator fatigue.
ZEPF-bIONIK Handle
The Lightred-Magenta ZEPF-bIONIK handle offers an ergonomic grip profile developed to support a relaxed hand posture. Its distinctive color coding assists with instrument identification and organization within the clinical tray setup.
Award-Winning Handle Design
The bIONIK handle won the Red Dot Design Award in 2010, the year of its launch. The jury of the Design Zentrum Nordrhein Westfalen in Essen, Germany, honored the bIONIK handleās ergonomic design, high-tech material, and exceptional lightness and durability.
Design Notes
The M5 design: the first shank is about 3 mm longer than standard and the sharpened working end is shortened, with a 0.95 mm thin, flexible and therefore highly tactile first shaft ā built for special subgingival curettage in tight, deep pockets (beyond 5 mm) and along narrow root surfaces.
Titanium for implant maintenance: the titanium working ends remove accumulated plaque film from implant necks without damaging the implant surface ā the material choice that makes routine maintenance around implants safe.
6-Month Warranty
This Helmut Zepf instrument is warranted against defects in materials and workmanship for its expected working life, which our research has shown to be 6 months from the date of delivery. See our Warranty page for full terms.
60-Day Returns ā Any Reason, Even If Used
Put this instrument to work in your practice. If it is not right for you, return it within 60 days of delivery for a full refund ā for any reason, even if it has been used.
FAQ
What teeth is the Gracey Curette 7/8 used for?
The 7/8 pattern is specifically designed for scaling and root planing on premolars and molars, addressing both buccal and lingual surfaces.
What does M5 Deep Scaling mean?
M5 refers to a more sharply angled blade geometry that enables deeper subgingival access compared to standard Gracey designs, making it suitable for deeper periodontal pockets.
Why choose titanium inserts?
Titanium inserts reduce instrument weight, enhance tactile feedback, and offer excellent resistance to corrosion and repeated sterilization cycles.
Compare With
| Brand | Gracey 7/8 ā Base Designation |
|---|---|
| Hu-Friedy | SG7/8 |
| American Eagle | AEG7-8 |
| PDT | R022 |
| Nordent | SCGR7-8 |
| Premier | BEUL-05607 / BE-1005015 / LT-1004813 / PremierAir-1004663 |
| LM-Dental | 207-208 |
| A. Titan | GR 7-8 |
Base pattern designations shown. Same clinical pattern, not identical manufacture ā see our Hygiene Instrument Comparison Chart.





