Clear Aligner Burs & Instruments

Clear aligner burs and instruments for every stage of an aligner case, on one page: Busch needle diamonds for interproximal reduction (IPR), the Helmut Zepf Strip Grip® for finishing with strips, Zepf aligner pliers for tray delivery and adjustment, and Busch ROTO-PRO burs and adhesive remover polishers for cleaning up composite once attachments come off. They work with Invisalign® and other clear aligner systems.
1IPR2Aligner Pliers3Adhesive Removal

Read more

Most clear aligner cases today are run by general dentists and orthodontists, and the same few instruments come out at almost every visit.

Clear Aligner Burs & Instruments
26 instruments
View as

The Clear Aligner Workflow, Stage by Stage

An aligner case moves through three instrument stages: making space with IPR, delivering and adjusting trays, and removing attachments at the end. The treatment plan from the orthodontist or aligner company sets IPR amounts and attachment positions; technique is the clinician's decision.

1. IPR — burs and strips

Open the contact with a medium-grit 858 or 859 needle, then refine with fine (red ring) and extra fine (yellow ring). The 8392 016 is a slender fine-grit needle many clinicians use on its own. Finish with abrasive strips held under tension in the Strip Grip® (pack of 2). Full detail is on IPR Burs & Instruments.

2. Aligner pliers — deliver and adjust trays

The Helmut Zepf vertical (33.720.43) and horizontal (33.720.44) aligner pliers seat and fine-adjust trays at delivery and check-in visits. The OrthoMASTER A-Punch (33.720.42) punches a 6 mm retention dimple so patients can get a fingernail under the tray.

3. Adhesive removal — ROTO-PRO and polishers

Aligner attachments are composite bonded to enamel, so the cleanup at the end of treatment is the same job as clearing adhesive after brackets come off. ROTO-PRO burs have a polygonal working part without sharp cutting edges, designed to break up cured composite while reducing the risk of damage to the enamel underneath.

Follow with the 9650 adhesive remover polishers (RA) to refine and polish the surface, or use the complete KieferDocs orthodontic polishing set (Busch No. 5433). More on these in our Orthodontic Bur Collection.

Clear aligner burs & instruments chart – by stage
Stage Product No. Notes
IPR — needle diamonds (Busch, FG)
Open 858 010 · 858 014 858 Medium · pack of 6
Open 859 010 · 859 014 · 859 016 · 859 018 859 Medium · pack of 6
Refine 8392 016 8392 Fine, red ring · pack of 2
Refine 8858 014 · 8859 010 · 8859 014 · 8859 018 8858 / 8859 Fine, red ring · pack of 2
Smooth 858EF 014 · 859EF 010 · 859EF 014 · 859EF 018 858EF / 859EF Extra fine, yellow ring · pack of 2
IPR — strips (Helmut Zepf)
Finish Strip Grip® strip holding tweezers 22.998.14 Diamond-coated tips · pack of 2
Tray delivery — aligner pliers (Helmut Zepf)
Seat Vertical aligner pliers 33.720.43 Seat and adjust trays
Seat Horizontal aligner pliers 33.720.44 Seat and adjust trays
Dimple OrthoMASTER A-Punch 33.720.42 6 mm retention dimple
Adhesive removal (Busch)
Remove 401 016 · 402 009 · 403 016 · 404 016 ROTO-PRO Non-cutting, FG · pack of 6
Polish 9650 030 · 9650 050 9650 Torpedo / flame, RA · pack of 6
Set KieferDocs orthodontic polishing set 5433 Complete set

Clinical Use

This collection covers the chairside instrument steps of clear aligner therapy: IPR to relieve mild to moderate crowding or correct tooth-size discrepancies, tray seating and adjustment, retention dimples, and removal of attachment composite at the end of treatment. Run the burs at the recommended speed with water spray — see our Dental Bur Speed Chart. For IPR technique, read our IPR guide.

Care and Reconditioning

Busch burs and polishers and Helmut Zepf instruments are reusable: clean, disinfect and sterilize them between patients according to the manufacturer's instructions and the symbols on each package. See our Dental Bur Reprocessing & Sterilization Guide and Orthodontic Instrument Sterilization & Reprocessing Guide.

Dental Instruments, Tools, Burs, Diamonds and Polishers Made In Germany

FAQ

What instruments do I need for clear aligner treatment?

Most practices keep three groups on hand: needle diamonds and a strip holder for IPR, aligner pliers for seating trays and punching retention dimples, and a non-cutting bur plus polishers for removing attachments at the end of treatment.

Do these work with Invisalign®?

Yes. These are general-purpose instruments for clear aligner therapy and work with Invisalign® and other aligner systems. DeutscheDT.com is not affiliated with Align Technology; Invisalign® is a registered trademark of Align Technology, Inc.

How do I remove aligner attachments?

Attachments are composite, so they come off the same way as bracket adhesive: break up the bulk with a non-cutting bur such as a ROTO-PRO, then refine and polish with an adhesive remover polisher. Technique and sequence are the clinician's decision.

Why are the ROTO-PRO burs not in the IPR collection?

IPR deliberately removes enamel with a diamond. ROTO-PRO burs are non-cutting and are designed to remove cured composite while reducing the risk of damage to the enamel, so they belong to the attachment-cleanup stage.

Where are these made?

The burs and polishers by Busch & Co. in Engelskirchen, Germany, since 1905; the Strip Grip® and aligner pliers by Helmut Zepf, which has been making instruments in Germany since 1921. DeutscheDT.com is the official US distributor for Busch. Questions? Call our experts at (917) 480-2682 ext 101.

Expert Help
Not sure which instrument fits your procedure?
Talk to our instrument specialists for selection assistance.
60-day returns
Helmut Zepf instruments are returnable within 60 days for any reason, even if used. Busch products: 60 days, unopened and unused.
Returns & Refunds
Warranty
Coverage differs by instrument line; the warranty page lists each one.
View warranty
Made in Germany, shipped from the US
Busch & Co. and Helmut Zepf instruments are made in Germany.

Compare /5